Implementation of a standard DMIS 5.2 command able to return the temperature of a specific sensor.
The command is:
QTEMP(tempSensNumber)
Where:
tempSensNumber: is the number of sensor to be tested, a DMIS extension the type of sensor can be identified with its name (x,y,z,p1,p2).
It is typically to read the temperature value for each axis/part sensor and can be used to send to the report the value of the temperature used for the compensation.