Correction of Linear Error With Scale Factors
From ArcoWiki
In addition to the full 24 parameter volumetric compensation of the CMM, it is possible to apply Scale Factores to correct some residual linear error. The factors shall be add to a figuration file as follow:
- Open the Folder ..\Data with Windows Explorer
- Open the File Machine.ini
- If not present, add in the bottom of the file the following lines:
[SFACTORS]
SFX1=1 SFY1=1 SFZ1=1 SFX2=1 SFY2=1 SFZ2=1
- Type, for each axis and for arm, the scale correction to be applied
- Press File -> Save
- Press File -> Exit
THE CORRECTION OF THE LINEAR ERRORS WITH SCALE FACTOR IT IS NOT RECOMMENDED AND IT IS PREFERABLE TO USE A FULL ERROR MAPPING.
SCALE FACTOR CALCULATION CÁLCULO DE LOS FACTORES DE ESCALA. CALCULO DO FATOR DA ESCALA
Fattore di scala = valore misurato del blocco / valore nominale del blocco
Scale factor= measured length of the gauge / nominal length of the block
Factor de escala= valor medido del bloco / valor nominal del bloco
Fator de escada= valor medido do bloco / valor nominal do bloco