Ballooning Report with Tolerance Name
From Version 3.6 it is implemented the possibility of creating HTML, EXCEL or TEXT reports with the name of the tolerance as label of the feature instead of the characteristic as previously possible in version 3.5.
This application is typically used in the so called "Ballooning Reporting" or "First Inspection Report", in which the items are "Balooned" on the drawing with a progressing number and need to be shown in the same order in the text measuring report.
Contents
Example of a standard HTML and TEXT report
F(P1)=FEAT/POINT,CART,0.0000,0.0000,0.0000,0.00000000,0.00000000,1.00000000
F(C1)=FEAT/CIRCLE,INNER,CART,0.0000,0.0000,0.0000,0.00000000,0.00000000,1.00000000,20.0000
FA(P1)=FEAT/POINT,CART,0.10000,0.10000,0.10000,0.00000000,0.00000000,1.00000000
FA(C1)=FEAT/CIRCLE,INNER,CART,0.20000,0.10000,0.20000,0.00000000,0.00000000,1.00000000,20.30000
V(TEXT)=VFORM/ALL
V(HTML)=VFORM/DME,'HTM',ALL
DISPLY/TERM,V(TEXT)
DISPLY/STOR,V(HTML)
F(P1)=FEAT/POINT,CART,0.0000,0.0000,0.0000,0.00000000,0.00000000,1.00000000
T(CORTOL_1)=TOL/CORTOL,XAXIS,-1.0000,1.0000
T(CORTOL_2)=TOL/CORTOL,YAXIS,-1.0000,2.0000
T(CORTOL_3)=TOL/CORTOL,ZAXIS,-3.0000,3.0000
OUTPUT/FA(P1),TA(CORTOL_1),TA(CORTOL_2),TA(CORTOL_3)
F(C1)=FEAT/CIRCLE,INNER,CART,0.0000,0.0000,0.0000,0.00000000,0.00000000,1.00000000,20.0000
T(DIAM_1)=TOL/DIAM,-1.0000,1.0000
OUTPUT/FA(C1),TA(CORTOL_1),TA(CORTOL_2),TA(CORTOL_3),TA(DIAM_1)
DISPLY/OFF
The above code would produce an HTML and TEXT report as follow:
In the Example, the label in the reports show the characteristic of the features, but, in the hypothetical drawing, the output lines would had be marked as balloons 1,2,3 etc.; under that condition the report won't fulfill the requirement of showing the balloons.
Example of a standard HTML and TEXT report with Comments
In order to make the report compliant, a possible solution would be necessary to use individual TEXT/OUTFIL
specifying the correct balloon:
F(P1)=FEAT/POINT,CART,0.0000,0.0000,0.0000,0.00000000,0.00000000,1.00000000
F(C1)=FEAT/CIRCLE,INNER,CART,0.0000,0.0000,0.0000,0.00000000,0.00000000,1.00000000,20.0000
FA(P1)=FEAT/POINT,CART,0.10000,0.10000,0.10000,0.00000000,0.00000000,1.00000000
FA(C1)=FEAT/CIRCLE,INNER,CART,0.20000,0.10000,0.20000,0.00000000,0.00000000,1.00000000,20.30000
V(TEXT)=VFORM/ALL
V(HTML)=VFORM/DME,'HTM',ALL
V(XLSX)=VFORM/DME,'XLSX',ALL
DISPLY/STOR,V(XLSX)
DISPLY/TERM,V(TEXT)
DISPLY/STOR,V(HTML)
F(P1)=FEAT/POINT,CART,0.0000,0.0000,0.0000,0.00000000,0.00000000,1.00000000
T(CORTOL_1)=TOL/CORTOL,XAXIS,-1.0000,1.0000
T(CORTOL_2)=TOL/CORTOL,YAXIS,-1.0000,2.0000
T(CORTOL_3)=TOL/CORTOL,ZAXIS,-3.0000,3.0000
TEXT/OUTFIL,'BALLOON 1'
OUTPUT/FA(P1),TA(CORTOL_1)
TEXT/OUTFIL,'BALLOON 2'
OUTPUT/FA(P1),TA(CORTOL_2)
TEXT/OUTFIL,'BALLOON 3'
OUTPUT/FA(P1),TA(CORTOL_3)
F(C1)=FEAT/CIRCLE,INNER,CART,0.0000,0.0000,0.0000,0.00000000,0.00000000,1.00000000,20.0000
T(DIAM_1)=TOL/DIAM,-1.0000,1.0000
TEXT/OUTFIL,'BALLOON 4'
OUTPUT/FA(C1),TA(CORTOL_1)
TEXT/OUTFIL,'BALLOON 5'
OUTPUT/FA(C1),TA(CORTOL_2)
TEXT/OUTFIL,'BALLOON 7'
OUTPUT/FA(C1),TA(CORTOL_3)
TEXT/OUTFIL,'BALLOON 8'
OUTPUT/FA(C1),TA(DIAM_1)
DISPLY/OFF
The above code would produce an HTML and TEXT report as follow:
In the Example, the comment help to identify the balloon, but still the programming would be incremented.
Use of the Tolerance Name in ARCO Report
By setting the Use Tolerance name in ARCO Control Panel the report would carry, instead of the label of the characteristic, the tolerance name, that would allow to create a ballooned report.
The following code:
F(P1)=FEAT/POINT,CART,0.0000,0.0000,0.0000,0.00000000,0.00000000,1.00000000
F(C1)=FEAT/CIRCLE,INNER,CART,0.0000,0.0000,0.0000,0.00000000,0.00000000,1.00000000,20.0000
FA(P1)=FEAT/POINT,CART,0.10000,0.10000,0.10000,0.00000000,0.00000000,1.00000000
FA(C1)=FEAT/CIRCLE,INNER,CART,0.20000,0.10000,0.20000,0.00000000,0.00000000,1.00000000,20.30000
V(TEXT)=VFORM/ALL
V(HTML)=VFORM/DME,'HTM',ALL
V(XLSX)=VFORM/DME,'XLSX',ALL
DISPLY/STOR,V(XLSX)
DISPLY/TERM,V(TEXT)
DISPLY/STOR,V(HTML)
F(P1)=FEAT/POINT,CART,0.0000,0.0000,0.0000,0.00000000,0.00000000,1.00000000
T(BALLOON_1)=TOL/CORTOL,XAXIS,-1.0000,1.0000
T(BALLOON_2)=TOL/CORTOL,YAXIS,-1.0000,2.0000
T(BALLOON_3)=TOL/CORTOL,ZAXIS,-3.0000,3.0000
OUTPUT/FA(P1),TA(BALLOON_1),TA(BALLOON_2),TA(BALLOON_3)
F(C1)=FEAT/CIRCLE,INNER,CART,0.0000,0.0000,0.0000,0.00000000,0.00000000,1.00000000,20.0000
T(BALLOON_4)=TOL/CORTOL,XAXIS,-1.0000,1.0000
T(BALLOON_5)=TOL/CORTOL,YAXIS,-1.0000,2.0000
T(BALLOON_6)=TOL/CORTOL,ZAXIS,-3.0000,3.0000
T(BALLOON_7)=TOL/DIAM,-1.0000,1.0000
OUTPUT/FA(C1),TA(BALLOON_4),TA(BALLOON_5),TA(BALLOON_5),TA(BALLOON_6)
DISPLY/OFF
would produce the following output:
Setting the Tolerance Name in ARCO Control Panel
The function can be activated in the Control Panel as follow:
- Open ARCO Control Panel
- Open the Advanced section
- Select the 'Reports tab
- Activate the check box Use Tolerance Name in the Arco Reporter frame.