+ | [[File:Gear_reducer.gif|thumb|right|400px|''https://en.wikipedia.org/wiki/Gear#/media/File:Gear_reducer.gif'']]<br /> | ||
+ | The gear package in Arco allows the measurement of [https://en.wikipedia.org/wiki/Gear Spur and Helical gears] with a CMM.<br /> | ||
+ | The measurement can be performed with: | ||
+ | *Point to Point (trigger) probe | ||
+ | *Continuous Scanning Probe | ||
+ | *[[PH20]] | ||
+ | <br /> | ||
+ | <br /> | ||
+ | By input the nominal data of a gear, Arco produce a program specifics for that gear automatically. <br /> | ||
+ | The preview allows the user to select all the metrologycal parameter for gear inspection such us: | ||
+ | *Limits and number of points for of the Involute | ||
+ | *Limits and number of points for if the Generatrix | ||
+ | *Safety radius for auto probe change | ||
+ | *Identification of the teeth to be measured | ||
+ | *Height of the gear | ||
+ | *Type of alignment within | ||
+ | **Current Reference System | ||
+ | **Plane and Cylinder | ||
+ | **Cylinder | ||
+ | **Synchronization of the tooth only | ||
+ | <gallery widths=400px heights=400px caption="Gear Program Definition"> | ||
+ | File:gearDefinition.png | ||
+ | File:Probe Selection.png | ||
+ | File:Full measuring Preview.png | ||
+ | </gallery> | ||
+ | |||
+ | <br /> | ||
+ | <br /> | ||
+ | |||
+ | |||
+ | Based on the parameter ARCO creates a full program with all the points to be takes and the correct alignment procedure.<br /> | ||
+ | At the end of the execution is generated a PDF report that goes with the international standards, the parameters evaluated are: | ||
+ | *Profile Error (Fa,ffA,fHa) | ||
+ | *Flank Error (Fb,ffb,fHb) | ||
+ | *Quality Class | ||
+ | *Left and Right Pitch Error (fp,Fp) | ||
+ | *Thickness and Run-out (Ues,Aes,Les,Fr) | ||
+ | |||
+ | <gallery widths=400px heights=400px caption="Gear Report"> | ||
+ | File:GearReport1.png | ||
+ | File:GearReport2.png | ||
+ | |||
+ | </gallery> | ||
+ | |||
+ | [[Category:Help_On_Line]] | ||
[[Category:ReadMe3.6]] | [[Category:ReadMe3.6]] |
Revision as of 16:05, 17 May 2018
The gear package in Arco allows the measurement of Spur and Helical gears with a CMM.
The measurement can be performed with:
- Point to Point (trigger) probe
- Continuous Scanning Probe
- PH20
By input the nominal data of a gear, Arco produce a program specifics for that gear automatically.
The preview allows the user to select all the metrologycal parameter for gear inspection such us:
- Limits and number of points for of the Involute
- Limits and number of points for if the Generatrix
- Safety radius for auto probe change
- Identification of the teeth to be measured
- Height of the gear
- Type of alignment within
- Current Reference System
- Plane and Cylinder
- Cylinder
- Synchronization of the tooth only
Based on the parameter ARCO creates a full program with all the points to be takes and the correct alignment procedure.
At the end of the execution is generated a PDF report that goes with the international standards, the parameters evaluated are:
- Profile Error (Fa,ffA,fHa)
- Flank Error (Fb,ffb,fHb)
- Quality Class
- Left and Right Pitch Error (fp,Fp)
- Thickness and Run-out (Ues,Aes,Les,Fr)