Difference between revisions of "Gear Inspection Module"

From ArcoWiki
Jump to: navigation, search
m (1 revision imported)
Line 1: Line 1:
 +
[[File:Gear_reducer.gif|thumb|right|400px|''https://en.wikipedia.org/wiki/Gear#/media/File:Gear_reducer.gif'']]<br />
  
 +
The gear package in Arco allows the measurement of [https://en.wikipedia.org/wiki/Gear Spur and Helical gears] with a CMM.<br />
 +
The measurement can be performed with:
 +
*Point to Point (trigger) probe
 +
*Continuous Scanning Probe
 +
*[[PH20]]
 +
<br />
 +
<br />
 +
By input the nominal data of a gear, Arco produce a program specifics for that gear automatically. <br />
 +
The preview allows the user to select all the metrologycal parameter for gear inspection such us:
 +
*Limits and number of points for of the Involute
 +
*Limits and number of points for if the Generatrix
 +
*Safety radius for auto probe change
 +
*Identification of the teeth to be measured
 +
*Height of the gear
 +
*Type of alignment within
 +
**Current Reference System
 +
**Plane and Cylinder
 +
**Cylinder
 +
**Synchronization of the tooth only
  
 +
<gallery widths=400px heights=400px caption="Gear Program Definition">
 +
File:gearDefinition.png
 +
File:Probe Selection.png
 +
File:Full measuring Preview.png
 +
</gallery>
 +
 +
<br />
 +
<br />
 +
 +
 +
Based on the parameter ARCO creates a full program with all the points to be takes and the correct alignment procedure.<br />
 +
At the end of the execution is generated a PDF report that goes with the international standards, the parameters evaluated are:
 +
*Profile Error (Fa,ffA,fHa)
 +
*Flank Error (Fb,ffb,fHb)
 +
*Quality Class
 +
*Left and Right Pitch Error (fp,Fp)
 +
*Thickness and Run-out (Ues,Aes,Les,Fr)
 +
 +
<gallery widths=400px heights=400px caption="Gear Report">
 +
File:GearReport1.png
 +
File:GearReport2.png
 +
 +
</gallery>
 +
 +
[[Category:Help_On_Line]]
 
[[Category:ReadMe3.6]]
 
[[Category:ReadMe3.6]]

Revision as of 16:05, 17 May 2018


The gear package in Arco allows the measurement of Spur and Helical gears with a CMM.
The measurement can be performed with:

  • Point to Point (trigger) probe
  • Continuous Scanning Probe
  • PH20



By input the nominal data of a gear, Arco produce a program specifics for that gear automatically.
The preview allows the user to select all the metrologycal parameter for gear inspection such us:

  • Limits and number of points for of the Involute
  • Limits and number of points for if the Generatrix
  • Safety radius for auto probe change
  • Identification of the teeth to be measured
  • Height of the gear
  • Type of alignment within
    • Current Reference System
    • Plane and Cylinder
    • Cylinder
    • Synchronization of the tooth only




Based on the parameter ARCO creates a full program with all the points to be takes and the correct alignment procedure.
At the end of the execution is generated a PDF report that goes with the international standards, the parameters evaluated are:

  • Profile Error (Fa,ffA,fHa)
  • Flank Error (Fb,ffb,fHb)
  • Quality Class
  • Left and Right Pitch Error (fp,Fp)
  • Thickness and Run-out (Ues,Aes,Les,Fr)